Martin Magnum 850 Specifiche

Navigare online o scaricare Specifiche per Macchina del fumo Martin Magnum 850. Martin Magnum 850 Specifications Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa

Sommario

Pagina 2

10 Opening The Machine: 1. DISCONNECT FROM MAINS SUPPLY. 2. Remove the 6 M4x10 pozidrive TAPTITE screws from the outside of the machine and store s

Pagina 3 - Haze machine principles:

11 HOW TO…. REFER TO SCHEMATICS / DIAGRAMS IN THE APPENDIX FOR MORE DETAILS How To Change A Heat Exchange: 1. Always try to change a HEAT EXCHA

Pagina 4 - CE mark

12 How To Change A Pump: 1. DRAIN ALL FLUID FROM THE SYSTEM FIRST. 2. DISCONNECT FROM MAINS SUPPLY. 3. Remove TOP COVER. 4. Disconnect the

Pagina 5

13 REFITTING: 12. Fit the BRASS FITTING to the front of the pump using a THREAD SEALANT COMPOUND. 13. Fit the new PUMP to the CHASSIS by inserting t

Pagina 6 - Specifications:

14 6. The PCB is mounted on 2 mounting posts which will need to be squeezed to remove the pcb. 7. Remove the HEATSINK from the PCB by removing the

Pagina 7

15 SPARE PARTS LISTS 240V Part Description Spare Part Number Comments PUMP PUMP 05761003 240V RED BODY (LARGE) PCB MAIN 62020005 MAIN CONT

Pagina 8 - PROCEED WITH EXTREME CAUTION

16 110V Part Description Spare Part Number Comments PUMP PUMP 05761001 110V BLACK BODY (LARGE) PCB MAIN 62020007 110V MAIN CONTROL PCB - TES

Pagina 9 - MAGNUM 800 MACHINE OVERVIEW

Drawn by : GS 28/03/2006 Drawing No. 2000-1A15423VIEWED FROM THE SOLDER SIDE OF THE DIN PLUG5, 0 - 10v INPUT, NEEDS 1.5v TO HEAT AND 2v -10v

Pagina 10 - The Inside:

Drawn by : GS 28/03/2006MAGNUM 800 REMOTEPCB PIN OUTSDrawing No. 2000-2A1 2 3 4 5 6PIN1, Not Used2, RED (+16v output)3, BLUE (0-10v input)4,

Pagina 12 - How To Change A Pump:

2 JEM Smoke Machine Training Program INDEX An Introduction To Smoke Technology: Smoke Machine Markets 3 Smoke Machine Principl

Pagina 16 - Fuse 240V 110V

NO OUTPUTIs the machine plugged in, turned on at the mains AND the power switch set to ON?Is the machine fully heated and ready to run?Check power and

Pagina 17 - OF THE DIN PLUG

PUMP PROBLEMSIs power getting to the pump?(set to full power and check 240V / 110V)See PCB PROBLEMSDoes piston seem to be moving?Is fluid travelling t

Pagina 18 - 1 2 3 4 5 6

HEATER PROBLEMSIs power getting through the thermal trip?(check 240V / 110V)THERMAL TRIP FAULT – RESET / REPLACEIs power getting to the thermal trip?(

Pagina 19

PCB PROBLEMSAPART FROM THE OBVIOUS FUSES / WIRING ETC. PCB FAULT FINDING IS TOO IN-DEPTH TO COVER HERE –PLEASE REFER SERVICING / REPAIR TO A QUALIFIED

Pagina 20

3 AN INTRODUCTION TO SMOKE TECHNOLOGY Smoke Machine Markets Jem / Martin smoke machines are categorised into 2 ranges: The Professional and the Cl

Pagina 21

4 CE mark All products that are produced by JEM / Martin carry the CE Certification. These products meet the requirements of the following EC Stand

Pagina 22

5 Searching for information on the INTERNET If you require information with regards to JEM / Martin Smoke, Haze and Heavy Fog products an ideal plac

Pagina 23 - NO OUTPUT

6 Which fluid can I use with my machine? X=NO O=YES Pro-Smoke Studio DX Mix Pro-Smoke Super ZR Mix Pro-Smoke High-density SP Mix I-Fog

Pagina 24 - PUMP PROBLEMS

7 Electrical AC power (EU models): 220-240 V nominal, 50 Hz AC power (US models): 110-120 V nominal, 60 Hz Main fuse (220-240 V power): 5 AT (slow

Pagina 25 - HEATER PROBLEMS

8 SERVICE OF MACHINES TOOLS AND THINGS: For successful servicing of a machine you will need some basic tools which are in good working order and

Pagina 26 - TO A QUALIFIED ENGINEER

9 MAGNUM 800 MACHINE OVERVIEW The Outside: ANALOGUE CONTROL

Commenti su questo manuale