10 Opening The Machine: 1. DISCONNECT FROM MAINS SUPPLY. 2. Remove the 6 M4x10 pozidrive TAPTITE screws from the outside of the machine and store s
11 HOW TO…. REFER TO SCHEMATICS / DIAGRAMS IN THE APPENDIX FOR MORE DETAILS How To Change A Heat Exchange: 1. Always try to change a HEAT EXCHA
12 How To Change A Pump: 1. DRAIN ALL FLUID FROM THE SYSTEM FIRST. 2. DISCONNECT FROM MAINS SUPPLY. 3. Remove TOP COVER. 4. Disconnect the
13 REFITTING: 12. Fit the BRASS FITTING to the front of the pump using a THREAD SEALANT COMPOUND. 13. Fit the new PUMP to the CHASSIS by inserting t
14 6. The PCB is mounted on 2 mounting posts which will need to be squeezed to remove the pcb. 7. Remove the HEATSINK from the PCB by removing the
15 SPARE PARTS LISTS 240V Part Description Spare Part Number Comments PUMP PUMP 05761003 240V RED BODY (LARGE) PCB MAIN 62020005 MAIN CONT
16 110V Part Description Spare Part Number Comments PUMP PUMP 05761001 110V BLACK BODY (LARGE) PCB MAIN 62020007 110V MAIN CONTROL PCB - TES
Drawn by : GS 28/03/2006 Drawing No. 2000-1A15423VIEWED FROM THE SOLDER SIDE OF THE DIN PLUG5, 0 - 10v INPUT, NEEDS 1.5v TO HEAT AND 2v -10v
Drawn by : GS 28/03/2006MAGNUM 800 REMOTEPCB PIN OUTSDrawing No. 2000-2A1 2 3 4 5 6PIN1, Not Used2, RED (+16v output)3, BLUE (0-10v input)4,
2 JEM Smoke Machine Training Program INDEX An Introduction To Smoke Technology: Smoke Machine Markets 3 Smoke Machine Principl
NO OUTPUTIs the machine plugged in, turned on at the mains AND the power switch set to ON?Is the machine fully heated and ready to run?Check power and
PUMP PROBLEMSIs power getting to the pump?(set to full power and check 240V / 110V)See PCB PROBLEMSDoes piston seem to be moving?Is fluid travelling t
HEATER PROBLEMSIs power getting through the thermal trip?(check 240V / 110V)THERMAL TRIP FAULT – RESET / REPLACEIs power getting to the thermal trip?(
PCB PROBLEMSAPART FROM THE OBVIOUS FUSES / WIRING ETC. PCB FAULT FINDING IS TOO IN-DEPTH TO COVER HERE –PLEASE REFER SERVICING / REPAIR TO A QUALIFIED
3 AN INTRODUCTION TO SMOKE TECHNOLOGY Smoke Machine Markets Jem / Martin smoke machines are categorised into 2 ranges: The Professional and the Cl
4 CE mark All products that are produced by JEM / Martin carry the CE Certification. These products meet the requirements of the following EC Stand
5 Searching for information on the INTERNET If you require information with regards to JEM / Martin Smoke, Haze and Heavy Fog products an ideal plac
6 Which fluid can I use with my machine? X=NO O=YES Pro-Smoke Studio DX Mix Pro-Smoke Super ZR Mix Pro-Smoke High-density SP Mix I-Fog
7 Electrical AC power (EU models): 220-240 V nominal, 50 Hz AC power (US models): 110-120 V nominal, 60 Hz Main fuse (220-240 V power): 5 AT (slow
8 SERVICE OF MACHINES TOOLS AND THINGS: For successful servicing of a machine you will need some basic tools which are in good working order and
9 MAGNUM 800 MACHINE OVERVIEW The Outside: ANALOGUE CONTROL
Commenti su questo manuale